Bugtraq mailing list archives

Juniper Advisory


From: security () procheckup com
Date: Fri, 24 Apr 2009 10:33:28 -0600

PR09-05: ScreenOS remote information disclosure on Juniper Netscreen ScreenOS Firewalls

Vulnerability found: 22nd March 2009

Vendor informed: 22nd March 2009

Severity: Low (information disclosure)

Description:

By simply requesting the about.html file, the firewall returns the version of ScreenOS and patch level used and the 
feature set.
No authentication is needed to retrieve this information on the firewall's OS. It is common to find exposed ScreenOS 
WebUI firewall management front-ends on the Internet, attackers might use the exposed information to carry out targeted 
attacks knowing the version and patch level of the firmware used.  


Successfully tested on:
Juniper Networks SSG 320 ScreenOS Version: 6.2.0r1.0
Juniper Networks netscreen SSG 520 ScreenOS Version:6.1.0r1.0
Juniper Networks netscreen 208 ScreenOS Version: 5.4.0r10.0

Proof of concept:

http://target-domain.foo/about.html
https://target-domain.foo/about.html

Returns:

                Juniper Networks, Inc.

                Version: 6.2.0r1.0 (Firewall+VPN)

                ScreenOS WebUI
                Copyright © 1997-2008 Juniper Networks, Inc.
                All Rights Reserved.


                For the latest technical information visit:
                http://www.juniper.net


Consequences: 

A remote attacker could recover information with regards to the target site's operating system version and patch level. 

This kind of information might be useful to attackers in certain scenarios. i.e.: when attempting to exploit published 

vulnerabilities in a outdated version of ScreenOS.


Fix:

Ensure that the firewall's management interface is disabled on the Internet connected interface, by disabling WeBUI 
within service 

options on the Internet connected interface.

Juniper Networks have released the 6.2.0r2.0, 6.2R2 and 5.4.0r12 software updates on the 8th April 2009 which solves 
the issue.

Vendor feedback:-

Juniper stated that no security advisory is needed to be released due to the low CVSS score of the vulnerability, and 
Juniper knew of the issue already. 

Procheckup found this issue affected different Juniper firewall firmware, going back to at least 2006. 

References: 

http://www.procheckup.com/Vulnerabilities.php
http://www.juniper.net/us/en/products-services/security/ssg-series/

Credits: Richard Brain of ProCheckUp Ltd (www.procheckup.com)


Legal:

Copyright 2009 Procheckup Ltd. All rights reserved.

Permission is granted for copying and circulating this Bulletin to the Internet community for the purpose of alerting 
them to 

problems, if and only if, the Bulletin is not edited or changed in any way, is attributed to Procheckup, and provided 
such 

reproduction and/or distribution is performed for non-commercial purposes.

Any other use of this information is prohibited. Procheckup is not liable for any misuse of this information by any 
third party.


Current thread: