nanog mailing list archives
Re: SMDS info
From: Michael Feldpusch <mef () bbnplanet com>
Date: Wed, 28 May 1997 15:46:49 -0500
SMDS is not that hard but the CSU needs to be configured properly in order for it to fuly work. Make sure that your timing is set for network, for it needs to be clocked from the could itself. Make sure you have your operating mode set for DXI, but this varies from vendor to vendor for the exact settings. Work with telco on thinning out the details. hope this helps mike At 07:15 PM 5/28/97 -0000, Michael Shields wrote:
Can anyone direct me to a good resource for info on configuring an ADC
SMDSU plugged into a HSSI port on my Cisco router? I've never had the pleasure of working with SMDS before and I don't like guessing when it needs to work before I ship it. Thanks.
I didn't have to do anything on mine except (a) turn down the access class because I wasn't using the full speed and (b) set it for c-bit framing. Do *not* configure your SMDS address into the SMDSU, configure it into the router. On the Cisco: interface Hssi1/0 encapsulation smds smds address c1XX.XXXX.XXXX smds multicast IP e1XX.XXXX.XXXX <ipaddress> <mask> smds multicast ARP e1XX.XXXX.XXXX <ipaddress> <mask> smds enable-arp That's it. SMDS is pretty ok, the two major flaws being that (a) no one is familiar with it and (b) it's fast-switched on a 7000. -- Shields, CrossLink.
=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=- Michael Feldpusch mef () bbnplanet com BBN Planet - Southeastern region 800-787-2638 Network Engineer 301-982-4600 x127 Infrastructure Engineering 301-489-8127 301-982-4605 (fax) "He who dies with the most toys, WINS!" =-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-=-= - - - - - - - - - - - - - - - - -
Current thread:
- SMDS info Brian Horvitz (May 28)
- Re: SMDS info Michael Shields (May 28)
- <Possible follow-ups>
- Re: SMDS info Michael Feldpusch (May 28)