nanog mailing list archives

Re: 7507 debug error


From: Jesper Skriver <jesper () skriver dk>
Date: Mon, 12 Jun 2000 23:17:32 +0200


HW problem, if you wasn't OIR'ing cards, I'd say you probably have a
faulty card.

On Mon, Jun 12, 2000 at 10:38:35PM +0200, Marc Teichtahl wrote:

can anyone translate this for me ?
Jun 12 21:41:07.679 CED: %RSP-3-RESTART: cbus complex
Jun 12 21:41:55.996 CED: %DBUS-3-SW_NOTRDY: DBUS software not ready
after
dbus_s
lot_enable(), elapsed 12032, status 0x48
-Traceback= 602A5284 602A6418 602B808C 60287EAC 602879B0 60290B18
6023F2CC
6023F
2B8
Jun 12 21:42:06.504 CED: %CBUS-3-CCBPTIMEOUT: CCB handover timed out,
CCB
0x5800
FF20, slot 0
-Traceback= 602BA350 602B7B98 602B8178 60287EAC 602879B0 60290B18
6023F2CC
6023F
2B8


-- 


Marc Teichtahl                                Manager, Data Network Engineering
Versa(tel Telecom                     NASDAQ: VRSA AEX: VERSA

US Cell: +1 650 248 7058              Dutch Cell: +31 6 21213104



/Jesper

-- 
Jesper Skriver, jesper(at)skriver(dot)dk  -  CCIE #5456
Work:    Network manager @ AS3292 (Tele Danmark DataNetworks)
Private: Geek            @ AS2109 (A much smaller network ;-)

One Unix to rule them all, One Resolver to find them,
One IP to bring them all and in the zone to bind them.



Current thread: