From: Bill Nickless <nickless () mcs anl gov>
Date: Mon, 29 Jan 2001 11:58:16 -0600



-----BEGIN PGP SIGNED MESSAGE-----

On the 6509:

set port negotiation <port> disable

You gotta do this even when you plug in a Cisco GSR (or did when I last 
tried it.)  Symptoms exactly the same.

At 05:44 PM 1/29/2001 +0000, Alison Gudgeon wrote:


Hi All,

I wonder if anyone else has experienced the following problem and could
perhaps offer a solution:

Interconnecting Catalyst 6509 Short Haul GBICs up to a Foudry Server Iron SX
with SC-SC fibre patch lead. The foundry sees a link light BUT the cisco
see's nothing connected.  What sprung to mind was auto neg. problems on the
CAT but auto neg is not a supported option so it can't be this?



Thanks in advance.


Alison

===
Bill Nickless    http://www.mcs.anl.gov/people/nickless      +1 630 252 7390
PGP:0E 0F 16 80 C5 B1 69 52 E1 44 1A A5 0E 1B 74 F7     nickless () mcs anl gov