Re: Bandwidth Control Question


From: sthaug () nethelp no
Date: Fri, 19 Dec 2003 18:29:04 +0100


The quite annoying thing about that is switching a PC-MC-2T3+ interface
from channelized (the default) to unchannelized causes a cbus complex
restart, which interrupts traffic through the router for a period of
time (the time varies based on the number of interfaces in the router).

Even with "service single-slot-reload-enable"?

Steinar Haug, Nethelp consulting, sthaug () nethelp no