nanog mailing list archives

Re: Layer 2 vs. Layer 3 to TOR


From: Olof Kasselstrand <olof.kasselstrand () gmail com>
Date: Fri, 13 Nov 2009 08:01:32 +0100

I would suggest doing a VC with the TOR switches. That way you can
have "one" switch for a lot of racks (I believe 10 would be the upper
limit if using Juniper). If you have a VC  you could do L3 and L2
where needed on every rack that the VC covers.

// Olof

2009/11/13 Łukasz Bromirski <lukasz () bromirski net>:
On 2009-11-12 22:37, David Coulson wrote:

The MX-series are pretty nice. That should be able to do VPLS PE,
however I've never tried it - MX240 did it pretty well last time I
tried. I've no clue how the cost of that switch compares to a cisco 4900
or something (not that a 4900 is anything special - L3 is all in
software).

For both 4948/4948-10GE and 4900M L3 is in hardware. For
4948/4948-10GE IPv6 is in software, for 4900M it's in hardware.

--
"Everything will be okay in the end. |                  Łukasz Bromirski
 If it's not okay, it's not the end. |       http://lukasz.bromirski.net




Current thread: