On Apr 4, 2010, at 11:29 47PM, Jorge Amodio wrote:

The N connectors were easier to deal with than the vampire taps.  To add
a node, you just "spliced" a new xceiver box onto the line where you
needed it by screwing a new length of cable into the new + existng
xceivers, then connecting the AUI drop cable from the box to the node.

I've to say it, the AUI cables were an absolute pain in the ass to deal with.

We had also a thick coax with the vampire taps and AUI fan outs from
Excellan. Dealing with the coax was not that bad since we made an
inverted U and had a coax run on each of the two vertical raisers this
particular building had.

The biggest challenge was to go from the raiser using the existing
horizontal conduits that were not that big, and run the AUI from the
XCVR to the fanout unit and then from that unit to each desk.

Before going to 10BaseT we used pre-standard LattisNet from SynOptics,
getting rid of the AUI was a relief.

Oh, the thick coax and the AUIs were lots of fun.  The 15-ping cables from the hosts to the AUIs were always coming 
loose, and the slide locks didn't help much.  The vampire taps tended to either not make good enough contact or to 
break the center conductor.  The N-connectors were easier to handle -- but cutting the cable and crimping on a pair 
took down the whole network.  

And then there was the time an electrician accidentally cut the coax and decided to splice it with black electrical 
tape...


                --Steve Bellovin, http://www.cs.columbia.edu/~smb