nanog mailing list archives

Re: L3 East cost maint / fiber 05FEB2012 maintenance


From: Jason Biel <jason () biel-tech com>
Date: Tue, 5 Feb 2013 11:33:48 -0600

Workaround is proper filtering and other techniques on the RE/Loopback to
prevent the issue from happening.

Should an upgrade be performed? Yes, but certainly doesn't have to have
right away or without notice to customers.

On Tue, Feb 5, 2013 at 11:23 AM, Jonathan Lassoff <jof () thejof com> wrote:

My hunch is that this is fallout and repairs from Juniper PR839412.
Only fix is an upgrade. Not sure why they're not able to do a hitless
upgrade though; that's unfortunate.

Specially-crafted TCP packets that can get past RE/loopback filters
can crash the box.

--j

On Tue, Feb 5, 2013 at 7:39 AM, Josh Reynolds <esseph () gmail com> wrote:
I know a lot of you are out of the office right now, but does anybody
have
any info on what happened with L3 this morning? They went into a 5 hour
maintenance window with expected downtime of about 30 minutes while they
upgraded something like *40* of their "core routers" (their words), but
also did this during some fiber work and completely cut off several of
their east coast peers for the entirety of the 5 hour window.

If anybody has any more info on this, on a NOC contact for them on the
East
Coast for future issues, you can hit me off off-list if you don't feel
comfortable replying with that info here.

Thanks, and I hope hope you guys are enjoying Orlando.

--
*Josh Reynolds*
esseph () gmail com - (270) 302-3552




-- 
Jason