Personally I prefer ENC_NA for single-byte. Some dissectors can mix endianess, like file-elf. What use in case like that? Maybe there is a need to add something new like ENC_NO_ENDIAN? (ENC_HOST_ENDIAN?) That can be used to fetch value that is always in host endian (magic number?) By the way: I use ENC_NA to improve readability too. I take a quick look and see my single-byte field, where around is a lot of multibyte fields. About copy-paste bugs: now there is a guard like Petri-Dish/pre-commit. On 15 December 2014 at 01:43, Jeff Morriss <jeff.morriss.ws () gmail com> wrote:
On 12/14/2014 03:03 PM, Bill Meier wrote:On 12/14/2014 2:22 PM, Stephen Fisher wrote:On Sun, Dec 14, 2014 at 01:44:19PM -0500, Bill Meier wrote:That being said, the convention (certainly not enforced) seems to be to use ENC_..._ENDIAN for fetching all integral types.Could this be related to when we made the change from using FALSE / TRUE to specify if its "big endian" in things like proto_tree_add_item() ?Good point ! fix-encoding-args.pl (used to do the change) just converted FALSE|0 to BIG_ENDIAN and etc, so the "convention" actually kind-of-happened because previously TRUE|1 or FALSE|0 were the only choices for the 'encoding-arg". So, I stand corrected. Maybe what I should be doing is converting all the single-byte fetches to use ENC_NA. Thoughts ?We discussed this some time ago; the consensus at the time seemed to be use ENC_*_ENDIAN for 1-byte fields: https://www.wireshark.org/lists/wireshark-dev/201107/msg00404.html ___________________________________________________________________________ Sent via: Wireshark-dev mailing list <wireshark-dev () wireshark org> Archives: http://www.wireshark.org/lists/wireshark-dev Unsubscribe: https://wireshark.org/mailman/options/wireshark-dev mailto:wireshark-dev-request () wireshark org?subject=unsubscribe
-- Pozdrawiam / Best regards ------------------------------------------------------------------------------------------------------------- Michał Łabędzki, Software Engineer Tieto Corporation Product Development Services http://www.tieto.com / http://www.tieto.pl --- ASCII: Michal Labedzki location: Swobodna 1 Street, 50-088 Wrocław, Poland room: 5.01 (desk next to 5.08) --- Please note: The information contained in this message may be legally privileged and confidential and protected from disclosure. If the reader of this message is not the intended recipient, you are hereby notified that any unauthorised use, distribution or copying of this communication is strictly prohibited. If you have received this communication in error, please notify us immediately by replying to the message and deleting it from your computer. Thank You. --- Please consider the environment before printing this e-mail. --- Tieto Poland spółka z ograniczoną odpowiedzialnością z siedzibą w Szczecinie, ul. Malczewskiego 26. Zarejestrowana w Sądzie Rejonowym Szczecin-Centrum w Szczecinie, XIII Wydział Gospodarczy Krajowego Rejestru Sądowego pod numerem 0000124858. NIP: 8542085557. REGON: 812023656. Kapitał zakładowy: 4 271500 PLN ___________________________________________________________________________ Sent via: Wireshark-dev mailing list <wireshark-dev () wireshark org> Archives: http://www.wireshark.org/lists/wireshark-dev Unsubscribe: https://wireshark.org/mailman/options/wireshark-dev mailto:wireshark-dev-request () wireshark org?subject=unsubscribe
Current thread:
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Evan Huus (Dec 13)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Bill Meier (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Stephen Fisher (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Bill Meier (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Anders Broman (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Evan Huus (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Jeff Morriss (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Michal Labedzki (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Alexis La Goutte (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Graham Bloice (Dec 15)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Stephen Fisher (Dec 15)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Stephen Fisher (Dec 14)
- Re: [Wireshark-commits] master f412c9a: Use ENC_BIG_ENDIAN when fetching FT_U?INT8 fields ... Bill Meier (Dec 14)