nanog mailing list archives
Re: Pad 1310nm cross-connects?
From: Måns Nilsson <mansaxel () besserwisser org>
Date: Sun, 20 Oct 2013 07:21:42 +0200
Subject: Pad 1310nm cross-connects? Date: Sat, Oct 19, 2013 at 07:33:19PM -0700 Quoting Chris Costa (ccosta92630 () gmail com):
What are the opinions/views on attenuating short, 1310nm LR cross-connects. Assume < 20m cable length and utilizing the same vendor optics on each side of the link. Considering the LR transmit spec doesn't exceed the receiver's high threshold value do you pad the receiver closer to the median RX range to avoid potential receiver burnout over time, or just leave it un-padded?
LR usually needs padding in that scenario, IMHO. This also applies to MMR interconnects or other "premises" / "campus" situations. 5 or 10dB depending on patching quality -- sometimes up to 15. The value is best determined by measuring the signal. Then compare the measurement with the line card / SFP datasheet and determine the amount of padding necessary. As you write, the damage from overload is gradual, so simply trusting "it works" is quite bad for longevity reasons. Not all line cards and / or optical modules report the input signal level, so a good meter sometimes is necessary. Get a good level meter, and a reasonably good light source for testing and calibration purposes. I'm happy with our purchase of SMLP4-4[0] from AFL Noyes. -- Måns Nilsson primary/secondary/besserwisser/machina MN-1334-RIPE +46 705 989668 Pardon me, but do you know what it means to be TRULY ONE with your BOOTH! [0] http://www.aflglobal.com/Products/Test-and-Inspection/Loss-Test-sets/SMLP4-4_Single-mode_Multimode_Loss_Test_Kits.aspx
Attachment:
signature.asc
Description: Digital signature
Current thread:
- Pad 1310nm cross-connects? Chris Costa (Oct 19)
- Re: Pad 1310nm cross-connects? Mikael Abrahamsson (Oct 19)
- Re: Pad 1310nm cross-connects? Justin M. Streiner (Oct 19)
- Re: Pad 1310nm cross-connects? Måns Nilsson (Oct 19)
- Re: Pad 1310nm cross-connects? Måns Nilsson (Oct 20)
- Re: Pad 1310nm cross-connects? Sam Roche (Oct 20)
- Re: Pad 1310nm cross-connects? Eric Litvin (Oct 20)
- Re: Pad 1310nm cross-connects? joel jaeggli (Oct 20)
- Re: Pad 1310nm cross-connects? Justin M. Streiner (Oct 20)
- Re: Pad 1310nm cross-connects? Leo Bicknell (Oct 20)
- <Possible follow-ups>
- Re: Pad 1310nm cross-connects? Brandon Butterworth (Oct 20)